Yamaha Amp Editor Uživatelský manuál Strana 204

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 211
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 203
Amp Editor Owner’s Manual
204
Appendix
Appendix
Alert message list
Alert messages that can be specified on the TXn, ACD1, and XMV, their content, and the appropriate responses,
are listed below.
“Single” will appear when an alert event occurs. “Continual” will appear when an alert event occurs and ends.
Some alert messages are displayed in Amp Editor. However, no alert messages are displayed on the ACD1 and the XMV.
If the problem is not solved, please contact your Yamaha dealer.
TXn
ACD1
XMV
Message
(shown in
Amp Editor)
Message
(shown on
TXn/ACD1)
Alert number
(shown on
XMV)
Content Response Initial type
Single/
Continual
Device problem
System error System error 001
The device has not started
up correctly.
Turn the power off, then turn on
after waiting at least 6 seconds. If
this does not solve the problem,
please initialize the memory.
Should this also fails, contact
your Yamaha dealer.
Fault Continual
——
Sub CPU Comm
error
—002 Fault Continual

Flash ROM
device error
Flash ROM
error
Fault Single
—— 003 Fault Continual

No current scene
found
Current scn lost
The current scene settings
saved in internal memory
have been lost.
Recall the scene. If this does not
solve the problem, contact your
Yamaha dealer.
Fault Single
——
No current
preset found
—016
A memory problem has
occurred.
Contact your Yamaha dealer. Fault Continual

Resume data
lost
Resume data
lost
The settings saved in
internal memory have
been lost.
Either the internal backup battery
has run low, or the device has
malfunctioned.
If a problem persists even after a
scene or preset is recalled,
consult your nearest Yamaha
dealer.
Fault Single
—— 015 Fault Continual
DSP error DSP error
A problem has occurred in
the internal DSP.
It is likely that the device has
malfunctioned; immediately stop
using the device and contact
your Yamaha dealer.
Fault Continual
——
DSP hardware
error
—007
The device has not started
up correctly.
Turn the power off, then turn on
after waiting at least 6 seconds. If
this does not solve the problem,
please initialize the memory.
Should this also fails, contact
your Yamaha dealer.
Fault Continual

Saving failed Saving failed
Fault Single
—— 004 Fault Continual

Illegal MAC
address
Ille
gal MAC adr 005 Fault Continual

Network
hardware error
Network HW
error
006 Fault Continual
——
Dante hardware
error
—008 Fault Continual
No battery No battery 010
The internal backup
battery has been
completely exhausted or is
not installed.
When you turn off the power, the
current settings will be lost, and
will return to the default values.
Please stop use immediately,
and contact your Yamaha dealer.
Fault Continual
Critical battery Critical battery 011
The internal backup
battery has run extremely
low, and it is possible that
the internal memory has
been cleared.
Error Continual
Low battery Low battery 012
The internal backup
battery has only a small
amount of power
remaining.
This does not affect the operation
of the device. However, if you
continue using the device, the
settings may be lost and reset to
the default values. Contact your
Yamaha dealer as soon as
possible.
Warning Single