BRKT
Bracket unit
7-31
63P3F11
3. Remove the lead holder
1
and rubber
spacers
2
from the stator, and then slide
them away from the stator.
4. Remove the stator
3
.
NOTE:
Place a clean cloth over the end of the arma-
ture shaft, hold it with a pair of pliers, and
then carefully slide the stator off of the arma-
ture.
5. Remove the armature from the PTT
motor base.
CAUTION:
Do not allow grease or oil to contact the
commutator.
6. Disconnect the PTT motor lead (sky
blue)
4
.
NOTE:
Hold the brush with a screwdriver as shown,
and then disconnect the PTT motor lead (sky
blue).
7. Remove the screw, disconnect the PTT
motor lead (light green)
5
, and then
remove the brushes
6
.
CAUTION:
• Do not pull the PTT motor leads out
from the stator.
• Do not touch the bimetal
a
, otherwise
the operation of the circuit breaker can
be affected.
Checking the power trim and tilt
motor
1. Measure the length of the brushes.
Replace if out of specification.
S60X7240
4
Brush length limit
a
:
4.8 mm (0.19 in)