Re
istration to obtain level meter c
cle
DME
SMC 0 500
settin
the c
cle for obtainin
the meter to 500 msec
SMC OK
GCMT 0 1 0
c
clicall
obtainin
ever
meter re
istered in "1"
GCMT OK
MTR 0 1 CUR -100 -500 -200 …
Remote Controller
obtainin
a meter re
istered in "1"
500msec
MTR 0 1 CUR -100 -500 -200 …
obtainin
a meter re
istered in "1"
:
:
:
QCMT 0 1 0
sto
in
the c
clical
rocess of obtainin
a com
onent meter re
istered in "1"
QCMT OK
Mute Control
DME
SMUT 0 ON
(turning mute on)
Remote Controller
SMUT OK
MUTE 0 ON
(notifying that the mute function is turned on)
Obtaining mute condition
DME
GMUT 0
(obtainin
mute condition)
Remote Controller
GMUT OK
MUTE 0 ON
(notif
in
that the mute condition is on
GPI OUT Control
DME
SGO 0 1 ON 2 OFF 3 ON
(turning GPI OUT CH1 on, CH2 off and CH3 on)
SGO OK
Pla
in
Back WAV file
DME
PWF 0 1
(playing back a file registered in WAV File Manager 1)
PWF OK
Stopping playback of a WAV file
DME
SWF 0
(stopping playback of a WAV file)
SWF OK
Remote Controller
Remote Controller
Remote Controller
DME Remote Control Protocol Specifications V3.1
18