Yamaha Robotics Robot Controller CC-Link Unit Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Bezpečnostní systémy pro řízení přístupu Yamaha Robotics Robot Controller CC-Link Unit. Yamaha Robotics Robot Controller CC-Link Unit User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - YAMAHA Robot Controller

OWNER'S MANUALYAMAHA Robot ControllerRCX SeriesUNIT

Strany 2

iiChapter 4 Troubleshooting1. Items to confirm before starting up CC-Link system ... 4-12. Meanings of LEDs on CC-Link compatible module ...

Strany 3 - Introduction

Chapter 1 OutlineContents1. Features ... 1-12. Mechanism ...

Strany 5 - [Precautions for wiring]

1Outline1-11. FeaturesCC-Link is the abbreviation of Control & Communication Link.The CC-Link system connects the robot controller and dispersed i

Strany 6 - 2006 YAMAHA MOTOR CO., LTD

Outline11-22. MechanismThe mechanism of communication is explained in this section to provide an understand-ing of how the robot controller and PLC op

Strany 7 - Warranty

1Outline1-33. Names of each part on the CC-Link compatible moduleThe part names of the CC-Link compatible module installed in the robot controller are

Strany 8

Outline11-44. Assignment of CC-Link compatible I/OThe I/O expressions used in the robot controller’s program language and the I/O expres-sions for the

Strany 9 - Contents

1Outline1-55.Shift of CC-Link system connection status and robot controller statusAlways start the CC-Link system specification robot controller in th

Strany 10 - Chapter 6 Appendix

1-6Outline15. Shift of CC-Link system connection status and robot controller statuse CC-Link system erroneous connection state due to following factor

Strany 11 - Chapter 1 Outline

1-71Outline5. Shift of CC-Link system connection status and robot controller statusr Transmission from CC-Link system erroneous connection state to CC

Strany 14 - 2. Mechanism

Chapter 2 ConnectionContents1. Confirming the CC-Link compatible module settings ... 2-12. Setting to the CC-Link system specifica

Strany 16 - Program language

2-12Connection1. Confirming the CC-Link compatible module settingsWith the CC-Link system specification robot controller, the CC-Link compatible modul

Strany 17

2-2Connection22. Setting to the CC-Link system specification controllerWhen connecting the CC-Link compatible module to an existing robot controller,

Strany 18

2-32Connection3. Setting the CC-Link compatible moduleTo connect the CC-Link system specification controller to the CC-Link system, the station No. an

Strany 19

2-4Connection23. Setting the CC-Link compatible module3.2 Setting the communication speedUsing the rotary switch BPS in front of the CC-Link compatibl

Strany 20

2-52Connection4. Noise measuresTwo ferrite cores must be mounted on the input power cable when connecting to the CC-Link system.4.1 Mounting the ferri

Strany 21 - Chapter 2 Connection

2-6Connection25. Connecting to the CC-Link systemThe CC-Link system cable must be connected to the CC-Link compatible module inorder to connect to the

Strany 22

2-72ConnectionnNOTE• Set the Board status parameter to"INVALID" when not using serialI/O boards.• When the Board status parameteris set to &

Strany 23 - Connection

12IntroductionThank you for purchasing the CC-Link compatible module. This CC-Link compatiblemodule is an option module that enables connection of the

Strany 24

2-8Connection26.1 Parameter setting for CC-Link serial I/O board1) Press the F 1 (PARAM) key in “SYSTEM” mode to enter “SYSTEM>PARAM”mode.2) Press

Strany 25 - 3.1 Setting the station No

2-92Connection4) Select the parameter with the cursor (↑/↓) keys.Fig. 2-6-3SYSTEM>PARAM>OP.BRD>SELECT V8.18 1.board conditionVALID2.remot

Strany 26

2-10MEMO

Strany 27 - 4. Noise measures

Chapter 3 CommunicationContents1. State when robot controller power is turned ON ... 3-12. Initial process for connecting to

Strany 29

3-13Communication1. State when robot controller power is turned ONThe CC-Link system specification robot controller always starts operation in servo O

Strany 30

3-2Communication32. Initial process for connecting to CC-Link systemThe initial data process must be carried out to correctly connect to the CC-Link s

Strany 31

3-33Communication3. Communication with master station PLCThe method for communicating with the master station PLC by using the robot program when the

Strany 32

3-4Communication33.2 Transmitting dataData is transmitted by writing the robot controller output port data into the master stationPLC’s input device.T

Strany 33 - Chapter 3 Communication

3-53Communication4.Direct connection by emulated serialization on parallel DIOThe master station PLC can exchange bit information data with the parall

Strany 34

22Safety Precautions (Always read before starting use)Always read this manual, the robot controller instruction manual and programming manualbefore us

Strany 35 - Communication

3-6Communication34. Direct connection by emulated serialization on parallel DIO1. Direct connection from SI n ( ) to DO n ( )Serial port input can be

Strany 36 - 2.1 Initial data process

3-73Communication4. Direct connection by emulated serialization on parallel D2. Direct connection from SO n ( ) to DI n ( )Parallel port input can be

Strany 37 - 3.1 Receiving data

3-8Communication35. Referring to communication dataThe ON/OFF information exchanged with the master station PLC can be referred to using the program-m

Strany 38 - 3.2 Transmitting data

Chapter 4 TroubleshootingContents1. Items to confirm before starting up CC-Link system ... 4-12. Meanings of LEDs on CC-Link com

Strany 40

4-14Troubleshooting1. Items to confirm before starting up CC-Link systemConfirm the following items before starting up the CC-Link system.12345678910C

Strany 41

4-2Troubleshooting42. Meanings of LEDs on CC-Link compatible moduleSDERRLRUNRD1 2 3 4 5 6 7 8 9 01 2 3 4 5 6 7 8 9 01 2 3 4 5 6 7 8 9 0Front of the un

Strany 42

4-34Troubleshooting3. TroubleshootingIf trouble occurs in the connection with the robot controller while starting up the CC-Linksystem or during opera

Strany 43

4-4Troubleshooting43. Troubleshooting3.2 Programming unit error display confirmation[Confirmation item 1]<Confirmation details>• “CC-Link Commun

Strany 44

4-54Troubleshooting3. Troubleshooting3.3 CC-Link compatible module LED confirmation[Confirmation item 1]<Confirmation details>• The LED display

Strany 45 - Troubleshooting

32[Precautions for installation]wWARNING• Always crimp, press-fit or solder the connector wire connections with the maker-designated tool, and securel

Strany 46

4-6Troubleshooting43. Troubleshooting3.4 Confirmation from master station PLC[Confirmation item 1]<Confirmation details>• Using the master stati

Strany 47 - 3. Troubleshooting

4-74Troubleshooting4. Error messages relating to CC-LinkThis section describes error messages relating to CC-Link compatible units. For other messages

Strany 48

4-8MEMO

Strany 49

Chapter 5 SpecificationsContents1. Profile... 5-12. Detail

Strany 51

5-15Specifications1. ProfileYAMAHA robot controller (4-station occupying)Remote input/outputSO (00): Emergency stop input status outputSO (01): CPU_OK

Strany 52

5-2Specifications5SO(140) to SO(147): General-purpose outputSO(150) to SO(157): General-purpose outputReservedInitial data process request flagNot use

Strany 53

5-35Specifications2. Details of remote input/output signalsSO (00): Emergency stop input status outputSO (01): CPU_OK status outputSO (02): Servo ON s

Strany 54

5-4Specifications52. Details of remote input/output signalsSI (00): Emergency stop inputSI (01): Servo ON inputSI (02): Service mode inputSI (03): Ste

Strany 55 - 1. Profile

5-55Specifications2. Details of remote input/output signalsSI(20) to SI(27): General-purpose input to SI(150) to SI(157): General-purpose inputInitia

Strany 56 - Specifications

42[Precautions for starting and maintenance]wWARNING• Do not touch the terminals while the power is ON.Failure to observe this could lead to malfuncti

Strany 57

5-6Specifications53. Dedicated input/output signal timing chart3.1 Initial data process for CC-Link connectiona) b) c) d) e) ononoffonoffonoffonoffof

Strany 58

5-75Specifications3. Dedicated input/output signal timing chart3.2 Servo ON and emergency stopa) b) c) d) e) f) g) h) i) j) k) ononoffonoffonoffonon

Strany 59

5-8Specifications53. Dedicated input/output signal timing chart3.3AUTO mode changeover, program reset and program executiona) b) 100ms or more 100ms o

Strany 60

5-95Specifications3. Dedicated input/output signal timing chart3.4 Stopping with program interlocka) b) c) d) e) f) g) h) i) ononoffonoffonoffonoffoff

Strany 61

5-10Specifications54. Sample programAn example for the following type of hardware configuration has been prepared for thissection.P100MXYx2nd unit sup

Strany 62

5-115Specifications4. Sample program[Robot program data assignment]* Variables used1st unit : A : Point No. in pallet2nd unit : B : Point No. in pal

Strany 63

5-12Specifications54. Sample program[PLC data assignment]X0 (*1) : Unit errorX1 (*1) : Local station data link statusX6 (*1) : Data link start norm

Strany 64 - 4. Sample program

5-135Specifications4. Sample program[Robot program]1st unit’s RCX40 ‘INIT ROUTINERESET SO2()RESET SO4()RESET DO4()A=101‘MAIN ROUTINEMOVE P,P100,Z=0GOS

Strany 65

5-14Specifications54. Sample program[PLC program]0574244464851639192103107P10X0M0M1M9038M0M2X6X7X0 X0F X1M4M4M8M8M9036X178X178X0F[PLS M0 ][SET M1 ][RS

Strany 66

5-155Specifications4. Sample program109137X17BX102X109X108X109X108 X10B X10CX108 X10C X10BX109M9036M9036X1F8X101 X100 X102(Y101 )(Y10E )(Y10F )(Y10B )

Strany 67

52WarrantyThe YAMAHA robot and/or related product you have purchased are warranted againstthe defects or malfunctions as described below.Warranty desc

Strany 68

5-16Specifications54. Sample program212214242X1F8X1FB X181 X180X182X182X189X188 X189X189X188 X18B X18CX188 X18C X18BM9036[RST Y1F8 ](Y181 )(Y18E )(Y18

Strany 69

5-175Specifications5. CC-Link compatible module specificationsThe CC-Link compatible module with the label is compatible with CC-Link Ver. 1.10.Limit

Strany 70

5-18MEMO

Strany 71

Chapter 6 AppendixContents1. Term definition ... 6-1

Strany 73

6-16Appendix1. Term definition1. CC-Link (Control & Communication Link)CC-Link is a registered trademark of CC-Link partner association.2. SAFE mo

Strany 74

OWNER'S MANUALOct. 2006Ver. 1.06 This manual is based on Ver. 1.06 of Japanese manual.© YAMAHA MOTOR CO., LTD. IM CompanyRobot ControllerAll righ

Strany 76 - OWNER'S MANUAL

iContentsChapter 1 Outline1. Features .................... 1-12. Mechanism .....

Komentáře k této Příručce